Bently Nevada 190501-02-00-01 Velomitor CT Velocity Transducer 190501-02-00-01
Why the 190501-02-00-01 Belongs in Your Reliability Program
When a machine train trips unexpectedly, the cost is never just the repair. Lost production, emergency labor, and unplanned downtime quickly dwarf the price of the sensor that could have flagged the fault. The Bently Nevada 190501-02-00-01 Velomitor CT Velocity Transducer is built for engineers who would rather see the trend than react to the failure.
This is a genuine Bently Nevada part, factory-configured with a 3/8-in 24 to 1/2-in 20 stud mount, a MIL-C-5015 connection interface, and agency approval option 01 for hazardous-area installation. It measures absolute casing velocity directly, so you get meaningful vibration data without the mounting complexity of a proximity probe system.
Technical Specifications That Matter
- Sensitivity: 3.94 mV/mm/s (100 mV/in/s) ±5% — a standard output that drops straight into existing velocity monitoring channels.
- Frequency response: 3.0 Hz to 900 Hz (180 to 54,000 cpm) ±1.0 dB, extending to 1.5 Hz to 1.0 kHz (90 to 60,000 cpm) ±3.0 dB for broader coverage.
- Amplitude linearity: ±2% to 63.5 mm/s pk (2.5 in/s pk), so high-energy faults stay within a trustworthy measurement range.
- Output bias voltage: 10.1 Vdc ± 1.0 Vdc, Pin A referenced to Pin B.
- Dynamic output impedance: <400 Ω typical.
- Operating temperature: -40°C to +85°C (-40°F to +185°F).
- Shock limit: 5000 g pk maximum.
- Case material: 316L stainless steel, 33 mm diameter, 82 mm height, 297 g typical.
- Mounting torque: 4.5 N-m ± 0.6 N-m (40 in-lbf ± 5 in-lbf).
Two specifications deserve a closer look. First, the internal electronics are isolated from the case, which reduces ground-loop noise in electrically noisy plants. Second, the transverse response stays below 5% of axial sensitivity, meaning the transducer reports motion along its axis rather than picking up cross-axis vibration that would distort your trend data.
Where This Transducer Earns Its Keep
Casing velocity measurement suits a wide range of rotating equipment. On cooling tower fans and large AC motors, the 3.0 Hz low-frequency limit captures the running speed and its early harmonics. On pumps and compressors, the extended response to 1.0 kHz helps surface blade-pass and gear-mesh frequencies before they escalate.
The hazardous-area approval package — Ex ia IIC T4 and AEx ia IIC T4 for Class I, Division 1, Groups A, B, C, D, plus Class II Groups E, F, G and Class III — means the same part number works in classified process areas. For a maintenance planner, that simplifies spares: one transducer covers both general-purpose and hazardous-duty locations.
Installation Notes for Field Engineers
The 190501-02-00-01 mounts in any orientation, which gives you flexibility on crowded bearing housings. Tighten to 4.5 N-m ± 0.6 N-m; over-torquing can stress the mounting surface and skew the base strain reading. The 316L stainless steel case and MIL-C-5015 connector tolerate 100% condensing humidity as long as the unit is not submerged.
Cable runs can extend to 305 metres (1,000 ft.) using cable part number 02173006 with no signal degradation. Plan your routing to keep the connector dry and strain-free, and verify the polarity convention: Pin A goes positive with respect to Pin B when velocity moves from the base to the top of the transducer.
Maintenance and Long-Term Value
Velocity transducers have no moving parts to wear out, so the reliability conversation shifts to installation integrity and cable condition. Inspect the mounting stud and connector periodically, and watch for drift in bias voltage, which often signals cable damage rather than sensor failure. With a 5000 g shock limit and a -40°C to +85°C operating window, this unit handles the thermal cycling and vibration that shorten the life of lesser sensors.
For plants standardizing on Bently Nevada instrumentation, keeping a 190501-02-00-01 on the shelf means faster turnaround when a channel goes down. Contact Bently Supply Arabia for Bently Nevada parts pricing and availability.
Frequently Asked Questions
Can the 190501-02-00-01 replace a proximity probe system?
No. It measures casing velocity, not shaft-relative displacement. Use it where absolute housing vibration is the parameter you need.
What cable length is supported?
Up to 305 metres (1,000 ft.) using cable part number 02173006, with no degradation of signal.
Does it work in hazardous areas?
Yes, with agency approval option 01, it carries Ex ia IIC T4 and AEx ia IIC T4 ratings for the listed Class I, II, and III environments.
What mounting hardware does this configuration include?
The 02 option provides a stud mount sized 3/8-in 24 to 1/2-in 20.
إصدارات أخرى من نفس السلسلة (190501)
جميع الإصدارات التالية تنتمي إلى نفس عائلة المنتج من Bently Nevada وتختلف في خيارات التكوين (الطول، نوع الموصل، الاعتمادات):
- 190501-00-00-CN - 190501-00-00-CN | Bently Nevada Velomitor CT…
- 190501-08-99-04 - 190501-08-99-04 | Bently Nevada Velomitor CT…
- 190501-00-00-00 - Bently Nevada 190501-00-00-00 Velomitor CT Velocity…
- 190501-00-00-04 - Bently Nevada 190501-00-00-04 Velomitor CT Velocity…
- 190501-01-00-00 - Bently Nevada 190501-01-00-00 Velomitor CT Velocity…
- 190501-01-00-01 - Bently Nevada 190501-01-00-01 Velomitor CT Velocity…
- 190501-01-00-CN - Bently Nevada 190501-01-00-CN Velomitor CT Velocity…
- 190501-01-99-CN - Bently Nevada 190501-01-99-CN Velomitor CT Velocity…
معلومات هذه القطعة
هذه القطعة من عائلة لا ننشر لها قواعد تفكيك أرقام (لعدم توفر وثيقة طلب رسمية قابلة للتحقق). يمكنك:
- الاطلاع على أدلة تفكيك أرقام القطع لمعرفة ما إذا كانت العائلة مشمولة.
- مراجعة أوراق البيانات الرسمية.
- إرسال الرقم إلينا للتحقق منه يدوياً قبل التسعير.
| رقم القطعة (SKU) | 190501-02-00-01 |
|---|---|
| رقم الطراز (MPN) | 190501-02-00-01 |
| العلامة التجارية | Bently Nevada |
| السعر | 250 |
اطلب عرض سعر
أرسل رقم القطعة والكمية المطلوبة وسنعاود التواصل معك بعرض السعر وتفاصيل التوريد.