Bently Nevada 190501-00-00-00 Velomitor CT Velocity Transducer 190501-00-00-00
What Is the 190501-00-00-00 Velomitor CT?
The Bently Nevada 190501-00-00-00 is a Velomitor CT Velocity Transducer engineered for continuous, reliable measurement of absolute casing vibration on rotating machinery. As a maintenance engineer, you need a transducer that delivers stable velocity data without constant attention. This model provides a 3.94 mV/mm/s (100 mV/in/s) sensitivity with ±5% tolerance, making it a direct, dependable choice for condition monitoring and protection systems.
The 190501-00-00-00 ships with no mounting stud and a MIL-C-5015 connection interface. Its 316L stainless steel case and 2-pin connector resist harsh plant environments. With a weight of just 0.297 kg, it mounts easily on bearing housings, gearboxes, and pump casings.
Key Technical Specifications
- Sensitivity: 3.94 mV/mm/s (100 mV/in/s) ±5%
- Frequency Response: 3.0 Hz to 900 Hz ±1.0 dB; 1.5 Hz to 1.0 kHz ±3.0 dB
- Operating Temperature: -40°C to +85°C (-40°F to +185°F)
- Output Bias Voltage: 10.1 Vdc ±1.0 Vdc, Pin A referenced to Pin B
- Dynamic Output Impedance: <400 Ω typical
- Amplitude Linearity: ±2% to 63.5 mm/s pk
- Maximum Cable Length: 305 metres (1,000 ft.) with part number 02173006
- Case Material: 316L stainless steel
- Mounting Torque: 4.5 N-m ±0.6 N-m (40 in-lbf ±5 in-lbf)
- Weight: <297 g (10.5 oz.) typical
These parameters mean you get accurate velocity data across common machine speeds, from low-speed fans to high-speed compressors. The wide operating temperature range supports installations in hot process areas or cold climates without signal drift.
Where the 190501-00-00-00 Delivers Value
This transducer excels on balance-of-plant assets where early fault detection protects production. On a forced-draft fan, the 3.0 Hz low-frequency response captures blade pass and imbalance issues before they escalate. For a reciprocating compressor, the ±2% linearity to 63.5 mm/s pk ensures reliable readings during high-vibration events. And on cooling tower motors, the 316L stainless steel housing and 100% condensing humidity limit keep the sensor alive in wet, corrosive conditions.
From a cost-benefit view, one 190501-00-00-00 can replace multiple lower-grade sensors that fail prematurely. Its internal electronics are isolated from the case, reducing ground loop problems that cause false trips. That means fewer nuisance shutdowns and lower maintenance labor over the asset lifecycle.
Installation and Maintenance Notes
Mount the transducer with a 33 mm diameter mounting surface and apply 4.5 N-m torque. Any orientation works, so you can position the connector for easy cable routing. Use the MIL-C-5015 interface with compatible cable assemblies, and respect the 305-metre maximum cable length to preserve signal integrity.
During routine rounds, inspect the connector for moisture or corrosion and verify the mounting torque has not loosened. The 5000 g shock limit protects against accidental impacts, but always follow the manufacturer's safety manual for handling and installation. For maintenance planning, the 190501-00-00-00 typically requires no calibration after installation, which simplifies your preventive maintenance schedule.
Compatibility and Sourcing
This Velomitor CT integrates with standard Bently Nevada monitoring systems that accept velocity transducer inputs. Because it uses a MIL-C-5015 connection and no mounting stud, you can pair it with common junction boxes and cable assemblies already in your storeroom.
Please verify current lifecycle status and availability with Bently Supply Arabia before ordering. As a supplier of genuine Bently Nevada parts, Bently Supply Arabia offers fast global shipping and competitive pricing for industrial MRO. Contact Bently Supply Arabia for Bently Nevada parts pricing and availability.
الأسئلة الشائعة
- What is the sensitivity of the 190501-00-00-00?
- It provides 3.94 mV/mm/s (100 mV/in/s) with ±5% tolerance.
- Does this model come with agency approvals?
- The 190501-00-00-00 has Agency Approval Option 00, which means no approvals. Intrinsically safe versions are available under other approval options.
- What connector does the 190501-00-00-00 use?
- It uses a MIL-C-5015 connection interface with a 2-pin 316L stainless steel connector on top.
- What is the maximum cable length for this transducer?
- You can run up to 305 metres (1,000 ft.) of cable, part number 02173006, with no signal degradation.
إصدارات أخرى من نفس السلسلة (190501)
جميع الإصدارات التالية تنتمي إلى نفس عائلة المنتج من Bently Nevada وتختلف في خيارات التكوين (الطول، نوع الموصل، الاعتمادات):
- 190501-00-00-CN - 190501-00-00-CN | Bently Nevada Velomitor CT…
- 190501-08-99-04 - 190501-08-99-04 | Bently Nevada Velomitor CT…
- 190501-00-00-00 - Bently Nevada 190501-00-00-00 Velomitor CT Velocity…
- 190501-00-00-04 - Bently Nevada 190501-00-00-04 Velomitor CT Velocity…
- 190501-01-00-00 - Bently Nevada 190501-01-00-00 Velomitor CT Velocity…
- 190501-01-00-01 - Bently Nevada 190501-01-00-01 Velomitor CT Velocity…
- 190501-01-00-CN - Bently Nevada 190501-01-00-CN Velomitor CT Velocity…
- 190501-01-99-CN - Bently Nevada 190501-01-99-CN Velomitor CT Velocity…
معلومات هذه القطعة
هذه القطعة من عائلة لا ننشر لها قواعد تفكيك أرقام (لعدم توفر وثيقة طلب رسمية قابلة للتحقق). يمكنك:
- الاطلاع على أدلة تفكيك أرقام القطع لمعرفة ما إذا كانت العائلة مشمولة.
- مراجعة أوراق البيانات الرسمية.
- إرسال الرقم إلينا للتحقق منه يدوياً قبل التسعير.
| رقم القطعة (SKU) | 190501-00-00-00 |
|---|---|
| رقم الطراز (MPN) | 190501-00-00-00 |
| العلامة التجارية | Bently Nevada |
| السعر | 212 |
اطلب عرض سعر
أرسل رقم القطعة والكمية المطلوبة وسنعاود التواصل معك بعرض السعر وتفاصيل التوريد.