Bently Nevada 190501-13-00-CN Velomitor CT Velocity Transducer 190501-13-00-CN
Product Overview
When continuous vibration monitoring on critical rotating machinery demands a transducer that survives harsh industrial environments, the Bently Nevada 190501-13-00-CN Velomitor CT delivers. This genuine Bently Nevada velocity transducer converts casing vibration into a precise electrical signal for condition monitoring systems. The 190501-13-00-CN ships with a quick disconnect stud (mounting hardware option 1 3) and a MIL-C-5015 connection interface (option 0 0), making it a drop-in solution for engineers who need reliable data without re-engineering the installation.
Key Specifications
- Sensitivity: 3.94 mV/mm/s (100 mV/in/s) ±5%
- Frequency response: 3.0 Hz to 900 Hz (180 to 54,000 cpm) ±1.0 dB
- Extended range: 1.5 Hz to 1.0 kHz (90 to 60,000 cpm) ±3.0 dB
- Operating temperature: -40°C to +85°C (-40°F to +185°F)
- Case material: 316L stainless steel, 33 mm diameter, 82 mm height
- Weight: 0.297 kg (10.5 oz.) typical
- Output bias voltage: 10.1 Vdc ± 1.0 Vdc, Pin A referenced to Pin B
- Maximum cable length: 305 metres (1,000 ft.) with no signal degradation
- Mounting torque: 4.5 N-m ± 0.6 N-m (40 in-lbf ± 5 in-lbf)
- Mounting angle: any orientation
Why This Transducer Earns Its Place
The 190501-13-00-CN is not a commodity sensor. Its 316L stainless steel case resists corrosion in offshore, chemical, and washdown environments. The internal electronics are isolated from the case, which reduces ground loop noise and protects signal integrity. Transverse response stays below 5% of axial sensitivity, so cross-axis vibration does not corrupt your readings. Amplitude linearity holds ±2% to 63.5 mm/s peak, giving you confidence across the full measurement range.
For engineers managing a mixed fleet of Bently Nevada monitors, this transducer integrates directly with standard 2-pin MIL-C-5015 cabling. The quick disconnect stud speeds up swap-outs during scheduled outages, cutting labor hours and reducing downtime cost. That is the ROI argument: fewer man-hours per sensor replacement, longer intervals between failures, and data you can trust for trend analysis.
Applications and Installation Notes
Use the 190501-13-00-CN on gas turbines, compressors, pumps, motors, and fans where casing velocity measurements drive your protection and diagnostic logic. The wide frequency response covers both low-speed machinery (1.5 Hz) and high-speed rotating equipment up to 60,000 cpm, so one transducer model simplifies spares inventory.
Installation follows standard practice: mount the transducer on a clean, flat surface with the supplied quick disconnect stud, torque to 4.5 N-m ± 0.6 N-m, and verify polarity — Pin A goes positive with respect to Pin B when velocity moves from base to top. Any orientation works. Keep cable runs within the 305-metre limit to preserve signal quality. For intrinsically safe installations, follow the applicable control drawing and verify your agency approval option matches the hazardous area classification.
Maintenance and Reliability
Inspect the mounting stud and connector periodically for corrosion, loosening, or moisture ingress. The operating temperature range of -40°C to +85°C and 100% condensing humidity rating mean the transducer tolerates wet, cold, and hot conditions without submersion. Shock limit is 5000 g peak. Magnetic field susceptibility stays below 0.0068 mm/s/gauss at 50 gauss, so nearby electrical equipment rarely disturbs the signal. Always follow the manufacturer's safety manual for inspection and handling.
Please verify current lifecycle status and availability with Bently Supply Arabia before ordering.
الأسئلة الشائعة
- What makes the 190501-13-00-CN different from a standard 190501?
- The -13-00-CN suffix defines the mounting hardware (quick disconnect stud), connection interface (MIL-C-5015), and country-specific agency approval (CN). Confirm these options match your installation before purchase.
- Can I use this transducer with existing Bently Nevada monitor systems?
- The MIL-C-5015 2-pin interface and 10.1 Vdc bias voltage are designed for compatibility with standard Bently Nevada velocity monitoring channels. Verify your monitor input specifications against the transducer output.
- What cable length is safe without signal loss?
- Up to 305 metres (1,000 ft.) using part number 02173006 cable with no degradation of signal, per the manufacturer's specification.
- Is the 190501-13-00-CN intrinsically safe?
- Agency approval option CN is country-specific. Intrinsically safe ratings (Ex ia IIC T4, AEx ia IIC T4) apply to approval options 01 through 04. Confirm your specific approval option and hazardous area requirements with Bently Supply Arabia.
إصدارات أخرى من نفس السلسلة (190501)
جميع الإصدارات التالية تنتمي إلى نفس عائلة المنتج من Bently Nevada وتختلف في خيارات التكوين (الطول، نوع الموصل، الاعتمادات):
- 190501-00-00-CN - 190501-00-00-CN | Bently Nevada Velomitor CT…
- 190501-08-99-04 - 190501-08-99-04 | Bently Nevada Velomitor CT…
- 190501-00-00-00 - Bently Nevada 190501-00-00-00 Velomitor CT Velocity…
- 190501-00-00-04 - Bently Nevada 190501-00-00-04 Velomitor CT Velocity…
- 190501-01-00-00 - Bently Nevada 190501-01-00-00 Velomitor CT Velocity…
- 190501-01-00-01 - Bently Nevada 190501-01-00-01 Velomitor CT Velocity…
- 190501-01-00-CN - Bently Nevada 190501-01-00-CN Velomitor CT Velocity…
- 190501-01-99-CN - Bently Nevada 190501-01-99-CN Velomitor CT Velocity…
معلومات هذه القطعة
هذه القطعة من عائلة لا ننشر لها قواعد تفكيك أرقام (لعدم توفر وثيقة طلب رسمية قابلة للتحقق). يمكنك:
- الاطلاع على أدلة تفكيك أرقام القطع لمعرفة ما إذا كانت العائلة مشمولة.
- مراجعة أوراق البيانات الرسمية.
- إرسال الرقم إلينا للتحقق منه يدوياً قبل التسعير.
| رقم القطعة (SKU) | 190501-13-00-CN |
|---|---|
| رقم الطراز (MPN) | 190501-13-00-CN |
| العلامة التجارية | Bently Nevada |
| السعر | 270 |
اطلب عرض سعر
أرسل رقم القطعة والكمية المطلوبة وسنعاود التواصل معك بعرض السعر وتفاصيل التوريد.